Open-loop S-Curves A2
52
A2
parameter
description
default
units
min
max
hidden
item
run
lock
out
ACCEL JERK IN 2
Rate of increase of
acceleration, up to
ACCEL RATE, when
increasing elevator
speed
ft/s
3
or
m/s
3
N Y
2.0 N Y
ACCEL JERK OUT 2
Rate of decrease of
acceleration to zero
when approaching
contract elevator
speed
ft/s
3
or
m/s
3
N Y
2.0
0.60
N Y
DECEL JERK IN 2
Rate of increase of
deceleration, up to
DECEL RATE, when
decreasing elevator
speed
ft/s
3
or
m/s
3
N Y
2.0
0.60
N Y
DECEL JERK OUT 2
Rate of decrease of
deceleration to zero
when slowing the
elevator to leveling
speed
ft/s
3
or
m/s
3
N Y
2.0
0.60
N Y
ACCEL RATE 3
Acceleration rate limit
ft/s
2
or
m/s
2
N Y
2.60
0.800
N Y
DECEL RATE 3
Deceleration rate limit
ft/s
2
or
m/s
2
N Y
2.60
0.800
N Y
ACCEL JERK IN 3
Rate of increase of
acceleration, up to
ACCEL RATE, when
increasing elevator
speed
ft/s
3
or
m/s
3
N Y
2.0
0.60
N Y
ACCEL JERK OUT 3
Rate of decrease of
acceleration to zero
when approaching
contract elevator
speed
ft/s
3
or
m/s
3
N Y
2.0
0.60
N Y
DECEL JERK IN 3
Rate of increase of
deceleration, up to
DECEL RATE, when
decreasing elevator
speed
ft/s
3
or
m/s
3
N Y
2.0
0.60
N Y
DECEL JERK OUT 3
Rate of decrease of
deceleration to zero
when slowing the
elevator to leveling
speed
ft/s
3
or
m/s
3
N Y
2.0
0.60
N Y