Closed-loop Power Data D2
126
FLUX REFERENCE
(Flux Reference)
Flux reference used by the vector control of the
drive.
FLUX OUTPUT
(Flux Output)
Measured value of the flux output.
SLIP FREQUENCY
(Slip Frequency)
Displays the commanded slip frequency of the
motor.
MOTOR OVERLOAD
(Motor Overload)
Displays the percentage of motor overload trip
level reached. Once this value reaches 100%
the motor has exceeded its user defined
overload curve and a motor overload alarm is
declared by the drive.
DRIVE OVERLOAD
(Drive Overload)
Displays the percentage of drive overload trip
level reached. Once this value reaches 100%
the drive has exceeded its overload curve and a
drive overload fault is declared.
FLUX CURRENT
(Flux Current)
Displays the flux producing current of the motor.
TORQUE CURRENT
(Torque Current)
Displays the torque producing current of the
motor.
FLUX VOLTAGE
(Flux Voltage)
Displays the flux voltage reference.
TORQUE VOLTAGE
(Torque Voltage)
Displays the torque voltage reference.
BASE IMPEDANCE
(Base Impedance)
Displays the drive calculated base impedance,
which is based on the RATED MTR PWR and
the RATED MTR VOLTS parameters. This
value is used to calculate the Per Unit values of
the system impedances (i.e. EXTERN
REACTANCE and STATOR RESIST).
EST NO LOAD CURR
(Estimated No Load Current)
Estimated no load current of the motor
calculated by the adaptive tune.
EST RATED RPM
(Estimated Rated RPM)
Estimated rated rpm of the motor calculated by
the adaptive tune.