![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624158.webp)
DC Choke Selection
158
DC Choke Selection
North America
Rated
Input
Voltage
Rated
HP
Rated
kW
Model
Number
Cube
size
Inductance
(mH)
Amps
10
7.5
-4018
B
0.38 mH
36 A
15
11
-4024
B
0.38 mH
36 A
20 15
-4034
C
n/a
*
n/a
380V
to
480V
25 18
-4039
C
n/a
*
n/a
7.5
5.5
-2028
A
0.38 mH
36 A
10
7.5
-2035
B
0.38 mH
36 A
15
11
-2047
B
0.12 mH
72 A
200V
to
240V
20 15
-2060
C
n/a
*
n/a
* DC choke internal to drive
European
Rated
Input
Voltage
Rated
kW
Model
Number
Cube
size
Inductance
(mH)
Amps
4
-4011
A
1.5 mH
18 A
5.5
-4015
A
1.5 mH
18 A
7.5
-4021
B
0.38 mH
36 A
11
-4028
B
0.38 mH
36 A
380V
to
440V
15 -4039
C
n/a
*
n/a
* DC choke internal to drive
Manufacturer Considerations:
When selecting a input reactor, the elevator load profile needs to be taking into account.
Consider the following when selecting a manufacturer.
•
Repeated 200% overloads current values
•
Heating of inductors due to overloads and harmonics
•
Saturation of inductor
•
Life of reactor
•
Ambient temperature vs. inductor current curve. The drive can operate at 50
°
C (120
°
F).