![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624064.webp)
Open-loop User Switches C1
64
Configure C0 menu
User Switches C1 submenu
C1
parameter
description
default
choices
hidden
item
run
lock
out
SPD COMMAND SRC
Speed Command
Source
MULTI-STEP analog
input
multi-step
serial
N Y
RUN COMMAND SRC
Run Command
Source
EXTERNAL TB1
external tb1
serial
extrn
N Y
MOTOR ROTATION
Allows user to
reverse direction of
motor rotation.
FORWARD forward
reverse
N Y
SPD REF RELEASE
Determines when
speed reference
release is asserted
(for use when the
drive controls the
mechanical brake)
REG RELEASE
reg release
brake picked
N Y
CONT CONFIRM SRC
Determines if an
external logic input is
used for contactor
confirm.
NONE none
external tb1
N Y
FAULT RESET SRC
Fault reset source
EXTERNAL TB1
external tb1
serial
automatic
N Y
OVERSPD TEST SRC
Determines external
logic source to initiate
overspeed test
EXTERNAL TB1
external tb1
serial
N Y
BRAKE PICK SRC
Determines the
source of the brake
pick command
(if drive controls
mechanical brake)
INTERNAL internal
serial
N Y
BRAKE PICK CNFM
Determines if a logic
input is used for
brake pick confirm
NONE none
external tb1
N Y
BRAKE HOLD SRC
Determines the
source of the brake
hold command.
(if drive controls
mechanical brake)
INTERNAL internal
serial
N Y
BRK PICK FLT ENA
Brake pick fault
enable(if drive
controls mechanical
brake)
DISABLE disable
enable
N Y
BRK HOLD FLT ENA
Brake hold fault
enable(if drive
controls mechanical
brake)
DISABLE disable
enable
N Y
DIR CONFIRM
Allows confirmation of
polarity of analog
speed command
DISABLE disable
enable
N Y
STALL TEST ENA
Stall Test function
enable
ENABLE disable
enable