![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624004.webp)
Ratings
4
Current Ratings
North American
Voltage
Class
Rated
HP
Rated
kW
Continuous
Output
General
Purpose
Current
Rating
Continuous
Output
Elevator
Duty Cycle
Current
Rating
150%
Output
Current
for 60 Sec
200%
Maximum
Output
Current
for 5 Sec
Cube
Size*
Model Number**
10
7.5
18 A
20.8 A
27 A
36 A
B
HPV600-4018-xxxx-xx
15
11
24 A
27.8 A
36 A
48 A
B
HPV600-4024-xxxx-xx
20
15
34 A
39.4 A
51 A
68 A
C
HPV600-4034-xxxx-xx
380V
to
480V
25
18
39 A
45.2 A
58.5 A
78 A
C
HPV600-4039-xxxx-xx
7.5
5.5
28 A
32.4 A
42 A
56 A
A
HPV600-2028-xxxx-xx
10
7.5
35 A
40.6 A
52.5 A
70 A
B
HPV600-2035-xxxx-xx
15
11
47 A
54.5 A
70.5 A
94 A
B
HPV600-2047-xxxx-xx
200V
to
240V
20
15
60 A
69.6 A
90 A
120 A
C
HPV600-2060-xxxx-xx
!
All ratings at 60/50Hz, 10kHz carrier frequency and based on a geared elevator application
!
Standard: CSA
European
Voltage
Class
Rated
kW
Continuous
Output
General
Purpose
Current
Rating
Continuous
Output
Elevator
Duty Cycle
Current
Rating
150%
Output
Current
for 60 Sec
200%
Maximum
Output
Current
for 5 Sec
Cube
Size*
Model Number**
4
11 A
12.7 A
16.5 A
22 A
A
HPV600-4011-xxxx-xx
5.5
15 A
17.4 A
22.5 A
30 A
A
HPV600-4015-xxxx-xx
7.5
21 A
24.3 A
31.5 A
42 A
B
HPV600-4021-xxxx-xx
11
28 A
32.4 A
42 A
56 A
B
HPV600-4028-xxxx-xx
380V
to
440V
15
39 A
45.2 A
58.5 A
78 A
C
HPV600-4039-xxxx-xx
!
All ratings at 60/50Hz, 10kHz carrier frequency and based on a geared elevator application
For more information on altitude, temperature, and carrier frequency derating, see page 6.
* Cube size dimensions, mounting holes, and weights are shown in page 152.
** From more information on model numbers, see page 6.