Closed-loop Analog Outputs C4
122
Choices
aux torq cmd
(Auxiliary Torque Command)
Additional torque command from auxiliary
source, when used.
D/A Units:
% rated torque
bus voltage
(DC Bus Voltage Output)
Measured DC bus voltage.
D/A Units:
% of peak in
current out
(Current Output)
Percent motor current.
D/A Units:
% rated current
drv overload
(Drive Overload)
Percent of drive overload trip level reached.
D/A Units:
% of trip point
flux current
(Flux Producing Current)
Measured flux producing current.
D/A Units:
% rated current
flux output
(Flux Output)
Measured flux output.
D/A Units:
% rated flux
flux ref
(Flux Reference)
Flux reference used by vector control.
D/A Units:
% rated flux
flux voltage
(Flux Producing Voltage)
Flux producing voltage reference.
D/A Units:
% rated volts
frequency out
(Frequency Output)
Electrical frequency.
D/A Units:
% rated freq
mtr overload
(Motor Overload)
Percent of motor overload trip level reached.
D/A Units:
% of trip point
power output
(Power Output)
Calculated power output.
D/A Units:
% rated power
pretorque ref
(PreTorque Reference)
Pre-torque reference.
D/A Units:
% base torque
slip freq
(Motor Slip Frequency)
Commanded slip frequency.
D/A Units:
% rated freq
spd rg tq cmd
(Speed Regulator Torque Command)
Torque command from speed regulator.
D/A Units:
% base torque
speed command
(Speed Command)
Speed command before
S-Curve
D/A Units:
% rated speed
speed error
(Speed Error)
Speed reference minus speed feedback.
D/A Units:
% rated speed
speed feedbk
(Speed Feedback)
Speed feedback used by speed regulator.
D/A Units:
% rated speed
speed ref
(Speed Reference)
Speed reference after S-Curve
D/A Units:
% rated speed
tach rate cmd
(Tachometer Rate Command)
Torque command from tach rate gain function.
D/A Units:
% base torque
torq current
(Torque Producing Current)
Measured torque producing current.
D/A Units:
% rated current
torq voltage
(Torque Producing Voltage)
Torque producing voltage reference.
D/A Units:
% rated volts
torque output
(Torque Output)
Calculated torque output.
D/A Units:
% rated torque
torque ref
(Torque Reference)
Torque reference used by vector control.
D/A Units:
% base torque
voltage out
(Voltage Output)
RMS motor terminal voltage.
D/A Units:
% rated volts