![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624078.webp)
Open-loop Elevator Data D1
78
Display D0 menu
Elevator Data D1 submenu
D1
parameter
description
units
hidden
item
SPEED COMMAND
Speed command before speed reference generator
ft/min or m/s
N
SPEED REFERENCE
Speed reference after speed reference generator
ft/min or m/s
N
SPEED FEEDBACK
Speed reference including all compensations
included (slip comp, etc.)
ft/min or m/s
N
ENCODER SPEED
Only used for diagnostics…
Display encoder speed in rpm
rpm N
LOGIC OUTPUTS
Displays the status of the logic outputs
1=true 0=false
N
LOGIC INPUTS
Displays the status of the logic inputs
1=true 0=false
N
Detailed descriptions
SPEED COMMAND
(Speed Command)
Monitors the speed command before the speed
reference generator (input to the S-Curve). This
command comes from either multi-step
references, speed command from analog
channel, or the serial channel.
SPEED REFERENCE
(Speed Reference)
Monitors the speed reference being used by the
drive. This is the speed command after passing
through the speed reference generator (which
uses a S-Curve).
SPEED FEEDBACK
(Speed Feedback)
Monitors the speed reference being used by the
drive that includes all compensations (slip comp,
etc.)
ENCODER SPEED
Only used for diagnostics…
Monitors encoder speed in rpm.
LOGIC OUTPUTS
(Logic Outputs Status)
This display shows the condition of the logic
outputs. (1=true 0=false)
LOGIC INPUTS
(Logic Inputs Status)
This display shows the condition of the logic
inputs. (1=true 0=false)
RUN/FAULT
SUB MENU
DATA ENT
HPV OPERATOR
LOGIC INPUTS
D1 000000000
Logic input 9
Logic input 1
RUN/FAULT
SUB MENU
DATA ENT
HPV OPERATOR
LOGIC OUTPUTS
D1 000000
Logic output 1
Logic output 4
Relay output 1
Relay output 2