Closed-loop Elevator Data D1
124
RX COM STATUS
(Serial Communications Status)
Serial communication status display.
Bit Severity Name
Description/Reason
0 Info
RX_INVALID_SETUP_ID
Invalid setup id on setup
message
1 Info
RX_SETUP_IN_RUN
A setup message to write
was received while the serial
run bit was set.
2 Fatal RX_TIMEOUT
A COMM FAULT was
declared because of a
communication time-out.
3 Info
/
Fatal
RX_INVALID_CHECKSUM
If COMM FAULT was
declared because of bad
message checksums.
4 Info
RX_INVALID_MESSAGE
Invalid header character in
message..
5 Info
RX_FIFO_OVERRUN
Overflow has occurred.
6 Info
RX_INVALID_RUN_ID
Set if the Cmd_Id sent in the
RUN MESSAGE is not in
range.
7 Info
RX_INVALID_MONITOR_ID
(Not available in Mode 2)
Set if the Monitor_Id
received in the run message
is not in range.
8 Info
RX_INVALID_FAULT_ID
Set if the Fault_Id sent in the
setup message is not in
range.
9 Info
RX_FAULT_DETECTED
COMM FAULT has been
detected
10 Info
Fault_Mode_1
(Not available in Mode 1)
Immediate Shutdown Mode
Bit Severity Name
Description/Reason
11 Info
Fault_Mode_2
(Not available in Mode 1)
Run Removal Shutdown
Mode
12 Info
Fault_Mode_3
(Not available in Mode 1)
Rescue Shutdown Mode
13
N/a
14
N/a
15 Fatal
RX_COMM_FAULT
COMM FAULT has been
declared by the drive
LOGIC OUTPUTS
(Logic Outputs Status)
This display shows the condition of the logic
outputs. (1=true 0=false)
LOGIC INPUTS
(Logic Inputs Status)
This display shows the condition of the logic
inputs. (1=true 0=false)
RUN/FAULT
SUB MENU
DATA ENT
HPV OPERATOR
LOGIC OUTPUTS
D1 000000
Logic output 1
Logic output 4
Relay output 1
Relay output 2
RUN/FAULT
SUB MENU
DATA ENT
HPV OPERATOR
LOGIC INPUTS
D1 000000000
Logic input 9
Logic input 1
RUN/FAULT
SUB MENU
DATA ENT
HPV OPERATOR
LOGIC OUTPUTS
D1 0000000000000000
Bit 0
Bit 15