Page
59
of
63
Step 8
–
The E-Lower Cord can now be removed through the slit in the Chassis.
Refitting / Replacement
Step 9 - Refitting is a reversal of the removal process noting the following point:
A)
When inserting the E-Lower Cord through the Slit, ensure the labelled face is facing the
Lift Motor.
B)
To re-attach the Toggle Switch to the Chassis, you must align the Toggle Switch threaded
holes with the holes in the Chassis and attach using the 3mm Allen Key and M5 x 10 CSK
Screws.
Traverse Idle Gear
Within this section it will explain the correct procedure on removing and reinstalling the
Traverse Idle Gear for servicing procedures or replacement.
Removal
Step 1 - Remove external covers off the hoist (refer to section 9.1)
Step 2
–
Remove the Wheels from the hoist (refer to section 9.11)
Step 3
–
Using a 2mm Allen Key, Remove the M3x12 Screw and M3 Nyloc Nut to release the
Traverse Idle Gear.
Step 4 - Split the male and female parts of the Traverse Idle Gear as shown and remove.
Ensure to grab the washers placed between each piece of the Traverse Idle Gears.