214325
233
Revision A
Figure 5.202: CLAAS Combine Display
5.
Use < or > key to select CUTT.HEIGHT LIMITS, and
press OK.
6.
Follow procedure displayed on screen to program
upper and lower limits of header into CEBIS (CLAAS
Electronic on-Board Information System).
Figure 5.203: CLAAS Combine Display
7.
Use < or > key to select SENSITIVITY CAC, and
press OK.
NOTE:
Setting sensitivity of AHHC system impacts reaction
speed of AHHC on the header.
8.
Use
–
key or + key to change setting of reaction speed,
and press OK key.
Figure 5.204: CLAAS Combine Display
9.
Use line (A) or value (B) to determine sensitivity setting.
NOTE:
The setting can be adjusted from 0
–
100%. When
sensitivity is adjusted to 0%, signals from sensing
bands have no effect on automatic cutting height
adjustment. When sensitivity is adjusted to 100%,
signals from sensing bands have maximum effect on
automatic cutting height adjustment. The recommended
starting point is 50%.