214325
191
Revision A
Figure 5.110: Gleaner S9
A - Tyton Terminal
B - Hydro Handle/Ground Speed Lever
C - Throttle Lever
D - Header Control Cluster
These are primary controls to be used to engage and use
auto header height control (AHHC) function.
Figure 5.111: Header Control Cluster
1.
With header running, set Lateral Tilt to MANUAL by
pressing switch (A) upward to MAN position.
2.
Engage AHHC by pressing switch (B) upward to
I
position.
Figure 5.112: AHHC on GSL
3.
Press AHHC control switch (A) on ground speed
lever (GSL) to engage AHHC. The header positions
itself in current setpoint position.