214325
156
Revision A
Calibrating Auto Header Height Control (Case Combines with Version 28.00 or Higher Software)
For best performance of the auto header height control (AHHC), perform these procedures with center-link set to D.
When setup and calibration are complete, adjust center-link back to desired header angle. Refer to Header Angle in
header operator
’
s manual for instructions.
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
1.
Ensure center-link is set to D.
Figure 5.39: Case IH Combine Display
2.
Select TOOLBOX on MAIN page, and then select
HEADER SETUP.
3.
Locate HEADER SUB TYPE field. It will be located on
either HEAD 1 or HEAD 2 tab.
4.
Select 2000 (A).
Figure 5.40: Case IH Combine Display
5.
Locate HEADER SENSORS and HEADER
PRESSURE FLOAT fields. They will be located on
either HEAD 1 or HEAD 2 tab.
6.
Select ENABLE (A) in HEADER SENSORS field.
7.
Select NO (B) in HEADER PRESSURE FLOAT field.