Figure 5.96: Calibration Progress
6.
A message appears in CALIBRATION WIZARD when
reel calibration has started. The reel will begin turning
slowly and increase to high speed. A progress bar is
provided. If necessary, touch red X to cancel.
Otherwise, wait for message that reel calibration has
completed successfully. Touch green check mark to
save calibrated settings.
Setting up Automatic Header Controls (Gleaner S9 Series)
Automatic header functions are configured on HEADER SETTINGS page.
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
Figure 5.97: Automatic Controls and Sensitivity
Settings
1.
Automatic Control Functions:
There are toggle
(OFF/ON) switches on HEADER SETTINGS page for
automatic control functions. For MacDon headers,
ensure following two functions are enabled as shown:
•
RTC (return to cut) (A)
•
AHHC (automatic header height control) (B)
All other switches are disabled (and are not
highlighted).
2.
The
Sensitivity
setting (C) controls how responsive a
control (RTC or AHHC) is to a given change in sensor
feedback. The setting fields are located directly below
toggle switches. To enter a new sensitivity setting, touch
setting field below specific toggle switch, and enter new
value using on-screen keyboard.
•
If combine does not change feeder position quickly
enough when in Auto Mode, increase sensitivity.
•
If combine hunts for a position in Auto Mode,
decrease sensitivity.
NOTE:
Recommended sensitivity starting points for MacDon
headers are:
•
50
for RTC (A)
•
60
for AHHC (B)