WFR A
PPENDICES
S
ECTION
A
PPENDIX
II
882
M86 S
ECURITY
U
SER
G
UIDE
Part 3: Troubleshooting
The text in this section explains how the server alerts the
administrator to a failed component, and what to do in the
event of a failure.
Hard drive failure
Step 1: Review the notification email
If a hard drive fails, a notification email is sent to the admin-
istrator of the server. This email identifies the failed hard
drive by its number (HD 1 or HD 2 on a 300 series model, or
HD 1 through HD 4 on a 500 series model). Upon receiving
this alert, the administrator should verify the status of the
drives by first going to the Hardware Failure Detection
window in the Web Filter Administrator console.
WARNING
: Do not attempt to remove any of the drives from the
unit at this time. Verification of the failed drive should first be
made in the Administrator console before proceeding, as data on
the server will be lost in the event that the wrong drive is removed
from the unit.
Step 2: Verify the failed drive in the Admin console
The Hardware Failure Detection window in the Web Filter
Administrator console is accessible via the
System > Hard-
ware Failure Detection
menu selection:
Power
(button) – When the power button is
pressed, the main power to the server is turned on.
When the power button is pressed again, the main
power to the server is removed but standby power
is still supplied to the server.