A-34
Engineering Guide CDA3000
Appendix A Formula bank
A.2.11 Motor lists
Three-phase AC motors with squirrel-cage rotor to DIN VDE 0530,
3000 rpm, 50 Hz, IP54 protection, internally cooled
Standard 3-phase AC
motor
3000 rpm, 50 Hz
Size
Power
P in kW
Efficiency
η
in %
Nominal
torque
M
n
in Nm
Mass
moment of
inertia
J in kgm²
Rated
current at
230/400 V
56S/2
0.09
50
0.31
0.000130
0.80/0.5
56L/2
0.12
49
0.41
0.000160
0.96/0.6
63S/2
0.18
57
0.63
0.000141
1,22/0.75
63L/2
0.25
59
0.86
0.000188
1.5/0.91
71S/2
0.37
69
1,25
0.00035
1.83/1.1
71L/2
0.55
75
1.87
0.000455
2.45/1.45
80S/2
0.75
72
2.58
0.000678
3.25/1.93
80L/2
1.1
78
3.73
0.000904
4.6/2.7
90S/2
1.5
78
5.1
0.00137
5.8/3.4
90L/2
2.2
82
7.4
0.00183
8.4/4.9
100S/2
3.0
73
10.0
0.00282
12.5/7.3
112M/2
4.0
80
13.3
0.00556
14.8/8.6
132S/2
5.5
85
18.3
0.00837
21.1/12.1
132S/2a
7.5
84
24.9
0.012
27.1/15.7
160M/2
11.0
87
36.0
0.033
37.3/21.6
160M/2a
15.0
88
49.0
0.045
48.1/28.1
160L/2
18.5
92
60.0
0.054
59.1/34.1
180M/2
22.0
91
71.0
0.073
74.1/43.1
200L/2
30.0
90
97.0
0.12
96.1/56.1
200L/2a
37.0
92
119.0
0.15
114.1/66.1
225M/2
45.0
93
145.0
0.22
148.1/81.1
250M/2
55.0
95
177.0
0.36
170.1/98.1
280S/2
75.0
93
241.0
0.61
-/135.1
280M/2
90.0
92
289.0
0.70
-/165.1
315S/2
110.0
93
353.0
1.46
-/202.1
315M/2
132.0
92
424.0
1.70
-/244.1
315M/2a
160.0
93
514.0
2.00
-/289.1
315M/2b
200.0
87
641.0
2.20
-/385.1
The data given represent mean values which may vary slightly depending on manufacturer.
Table 7.25
Standard 3-phase AC motor, 3000 rpm, 50 Hz