Engineering Guide CDA3000
4-35
4 Software functions
DE
EN
1
2
3
4
5
6
7
A
A HTL encoder (see Figure 4.24) can be connected to terminals X2:11
and 12. Permissible pulse counts are in the range from 32 pulses per rev
to 16384 pulses per rev (2
n
where n=5 to 14).
Figure 4.24
Block diagram, HTL output circuit
Input signals
Figure 4.25
Example of a quick jog driving profile for two directions of rota-
tion (ASTER=DRV_4)
The output signals are shown in Figure 4.14.
User data set switchover (switchable offline)
S1
S2
Active UDS
Example
0
0
UDS 1 for application 1
x-axis, traction drive
1
0
UDS 2 for application 2
y-axis, traction drive
0
1
UDS 3 for application 3
z-axis, lifting drive
1
1
UDS 4 for application 4
Sorting belt
Table 4.13
User data set switchover
t [ms]
0
f [Hz]
v [m/s]
0
1
0
1
STR
STL
- 303-FMAX1
303-FMAX1
594-STPR1
590-ACCR1