![Lust CDA3000 Engineering Manual Download Page 204](http://html.mh-extra.com/html/lust/cda3000/cda3000_engineering-manual_1950411204.webp)
Engineering Guide CDA3000
4-31
4 Software functions
DE
EN
1
2
3
4
5
6
7
A
(ASTER=DRV_3)
Traction and lifting drive (configuration 3)
Figure 4.19
Control terminal assignment with ASTER=DRV_3
The remaining configuration of control terminals X2:15 to 20 (outputs)
and X3 is as shown in Figure 4.14 and Figure 4.16.
Function
Application
•
Clock drive with time-optimized
quick jog driving profile or
•
Quick jog/slow jog driving profile
•
Application switchover
•
Evaluation of safety limit switches
•
Rack drive
•
Spindle drive
•
Trolley drive
•
Lifting drive
•
etc.
X2
Function
1
Reference voltage 10 V, 10 mA
2
User data set switchover
3
Selection of slow jog
4
Actual frequency
0 ... 10 V corresponding to
0 ... FMAX
5
6
Auxiliary voltage 24 V max.
200 mA
7
8
Power stage hardware enable
9
Start/Stop quick jog clockwise
10
Start/Stop quick jog
anti-clockwise
11
Limit switch right
12
Limit switch left
13
Auxiliary voltage 24 V
14
DGND
S4
ENPO
STR
S3
N1
STL
S2
S1