Engineering Guide CDA3000
4-29
4 Software functions
DE
EN
1
2
3
4
5
6
7
A
(ASTER=DRV_2)
Traction and lifting drive (configuration 2)
Figure 4.17
Control terminal assignment with ASTER=DRV_2
The remaining configuration of control terminals X2:15 to 20 (outputs)
and X3 is as shown in Figure 4.14 and Figure 4.16.
Function
Application
•
Clock drive with time-optimized
quick jog driving profile or
•
Quick jog/slow jog driving profile
•
Application switchover
•
Switchover of setting when load
changed
•
Conveyor belt
•
Trolley drive
•
Rack drive
•
Spindle drive
•
Lifting drive
•
etc.
X2
Function (1...10)
1
Reference voltage 10 V, 10 mA
2
User data set selection
3
4
Actual frequency
0 ... 10 V corresponding to
0 ... FMAX
5
6
Auxiliary voltage 24 V max.
200 mA
7
8
Power stage hardware enable
9
Start/Stop quick jog clockwise
10
Start/Stop quick jog anti-clock-
wise
11
Selection of slow jog
12
Characteristic data set
switchover
13
Auxiliary voltage 24 V
14
DGND
S4
ENPO
STR
S3
N1
STL
S2
S1