4-16
Engineering Guide CDA3000
4 Software functions
4.2.1 Specification
of control
terminals
X3
PTC terminal
PTC, Klixon evaluation or linear temperature
transmitter
X4
RS232 terminal X4
for D
RIVE
M
ANAGER
or K
EY
P
AD
KP200
X10
Voltage supply for communi-
cation module
+ 24 V, ground
X11
CAN-In / PROFIBUS-DP
X12
CAN-Out
X13
Address coding plug
X15
User module UM-8I4O
Voltage supply,
8 digital inputs,
4 digital outputs
(1)
Reset button
(2)
Boot button
No.
Designation
Function
Table 4.4
Key to Figure 4.11
Des.
Terminal
Specification
floating
Analog inputs
ISA00
X2-2
•
U
IN
= +10 V DC,
±
10 V DC
I
IN
= (0) 4-20 mA DC, software-switchable to:
•
24 V digital input, PLC-compatible (IEC1131)
•
Switching level Low/High: <4.8 V / >8 V DC
•
Resolution 10-bit
•
R
in
=110k
Ω
•
Floating against digital ground
U:
±
1% of MV
I:
±
1% of MV
ISA01
X2-3
•
U
IN
= +10 V DC, software-switchable to:
•
24 V digital input, PLC-compatible (IEC1131)
•
Switching level Low/High: <4.8 V / >8 V DC
•
Resolution 10-bit
•
R
in
=110 k
Ω
•
Floating against digital ground
U:
±
1% of MV
Analog output
MV = measured value
Table 4.5
Specification of control terminals