Engineering Guide CDA3000
3-5
3 Selection of inverter module
DE
EN
1
2
3
4
5
6
7
A
3.1.1 Acceptance
tests
Explanation of the “Acceptance tests and standards” table
Acceptance tests /
Standards /
Directives
Characteristic data
CE
The inverter modules conform to the requirements for installation in a
machine or system under the terms of the Low Voltage Directive.
Approvals
c
U
L
(in preparation)
Conformance to
standards
•
Fitting-out of power installations with electronic equipment
E50178
•
EMC
1)
interference immunity
IEC 1000-4-2 / EN 61000-4-2
IEC 1000-4-3 / EN 61000-4-3
IEC 1000-4-4 / EN 61000-4-4
IEC 1000-4-5 / EN 61000-4-5
•
EMC, line-borne and radiated interference emission
EN 50081-1 and EN 50081-2
IEC 55011 integrated radio interference suppression level A
2)
/
B
2)
for inverter modules to 7.5 kW.
For inverter modules 11 to 90 kW a wide range of filters is availa-
ble to ensure conformance to IEC 55011.
•
All devices conform to the product norm
EN618000-3 for speed-adjustable electric drives.
1) EMC = Electromagnetic compatibility
2) Motor cable length - See section 6.4
Table 3.3
Acceptance tests/Standards
Standard
Test
Comments
EN 61000-4-2
•
By touch
Discharge 6 kV
•
In air
Discharge 8 kV
Test of immunity to electrostatic dis-
charge (ESD)
EN 61000-4-3
•
26-1000 MHz (10 V/m)
Test of the electromagnetic field
EN 61000-4-4
•
at control terminals 2 kV
•
on mains and motor cable
Impulse voltage 4 kV
Test of immunity to rapid transient
electrical interference (burst)
EN 61000-4-5
•
Conductor / conductor
1 kV
•
Conductor / ground
2 kV
Immunity to voltage surge
Table 3.4
Explanation of the “Acceptance tests and standards” table