![Lust CDA3000 Engineering Manual Download Page 207](http://html.mh-extra.com/html/lust/cda3000/cda3000_engineering-manual_1950411207.webp)
4-34
Engineering Guide CDA3000
4 Software functions
(ASTER=DRV_4)
Traction and lifting drive (configuration 4)
Figure 4.23
Control terminal assignment with ASTER=DRV_4
(1) The encoder is evaluated only in control mode FOR.
The remaining configuration of control terminals X2:15 to 20 (outputs)
and X3 is as shown in Figure 4.14 and Figure 4.16.
Function
Application
•
Clock drive with time-optimized
quick jog driving profile
•
Switchover for application
•
Encoder evaluation
•
Conveyor belt
•
Rack drive
•
Spindle drive
•
Trolley drive
•
Lifting drive
•
etc.
X2
Function
1
Reference voltage 10 V, 10 mA
2
User data set switchover
3
4
Actual frequency
0 ... 10 V corresponding to
0 ... FMAX
5
6
Auxiliary voltage 24 V max.
200 mA
7
8
Power stage hardware enable
9
Start/Stop clockwise
10
Start/Stop anti-clockwise
11
Encoder track A
12
Encoder track B
13
Auxiliary voltage 24 V
14
DGND
ENPO
STR
N1
STL
S2
S1
N2
A
B
(1)