Using Synchronous V.25bis Connections
14-13
Troubleshooting a Synchronous V.25bis Connection
Troubleshooting a Synchronous V.25bis Connection
Most synchronous configurations come up with very little trouble if you have
configured the PortMaster using information from your carrier. If you have problems,
use the information in this section to debug your configuration.
If you are having trouble with a V.25bis dial-up connection to location
Locname
, verify
the following:
•
The error counters should be 0 except for a small number of abnormal termination
errors resulting from plugging cables in or out. If your error counters are nonzero,
the problem is external to the PortMaster.
•
Verify that you are using the correct cables and that they are attached securely to
the correct port. Not all WAN ports are capable of the same speeds.
•
Verify that the DIP switch is set to V.35 for Lucent cables and that you are plugged
into the correct V.35 interface on your CSU/DSU.
•
Verify that the CSU/DSU or synchronous terminal adapter is providing the clock to
the PortMaster. The CSU/DSU or terminal adapter can generate the clock or receive
it from the carrier.
•
Verify that the CSU/DSU or synchronous terminal adapter is configured properly.
•
To view the PPP negotiation, use the following commands:
Command>
set
console
w1
Command>
set
debug
0x51
Command>
dial
Locname
For more information about the interpreting the results of the debug command,
refer to the “PortMaster Troubleshooting Guide.”
After you verify that the PPP negotiation is correct, enter the following commands
to turn off the debug utility:
Command>
set
debug
off
Command>
reset
console
•
Contact your carrier to review your configuration and the status of their line.
Summary of Contents for PortMaster
Page 16: ...Contents xvi Configuration Guide for PortMaster Products...
Page 26: ...Subscribing to PortMaster Mailing Lists xxvi PortMaster Configuration Guide...
Page 32: ...Basic Configuration Steps 1 6 PortMaster Configuration Guide...
Page 114: ...Configuring WAN Port Settings 6 12 PortMaster Configuration Guide...
Page 128: ...Configuring Login Users 7 14 PortMaster Configuration Guide...
Page 158: ...Restricting User Access 9 16 PortMaster Configuration Guide...
Page 168: ...Configuring Ports for Modem Use 10 10 PortMaster Configuration Guide...
Page 222: ...Frame Relay Subinterfaces 13 16 PortMaster Configuration Guide...
Page 236: ...Troubleshooting a Synchronous V 25bis Connection 14 14 PortMaster Configuration Guide...
Page 252: ...Using ISDN for On Demand Connections 15 16 PortMaster Configuration Guide...
Page 264: ...Using ISDN for Internet Connections 16 12 PortMaster Configuration Guide...
Page 276: ...Configuration Steps for Dial In Access 17 12 PortMaster Configuration Guide...
Page 286: ...Configuration Steps for Shared Device Access 18 10 PortMaster Configuration Guide...
Page 296: ...Troubleshooting a Leased Line Connection 19 10 PortMaster Configuration Guide...
Page 310: ...B 4 PortMaster Configuration Guide...
Page 352: ...Command Index Command Index 6 PortMaster Configuration Guide...