Ring Setup and Testing: Integration Procedures
Final Operations
...........................................................................................................................................................................................................................................................
6 - 1 9
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 9
Click
Send
to issue the command.
Result:
The Response Window should display the command
followed by a
COMPLD
indication.
............................................................................................................................................................................
Step 10
Repeat Step 1 through Step 3 to verify no further cross-connects exist.
............................................................................................................................................................................
Step 11
Verify that no alarm LEDs are lit and no
FAULT
LED is lit on any
circuit pack.
If any alarm is present, refer to 365-372-326, Metropolis
®
DMXtend
Access Multiplexer, Alarm Messages and Trouble Clearing Guide.
Clear PM Registers
The following steps will clear all the performance monitoring registers:
Step 1
Use the scroll bar in the
Command Builder
window to scroll down to
the
init-reg-all
command.
............................................................................................................................................................................
Step 2
Click on the
init-reg-all
command. Select all from the <Default AID>
and double click on the 15-min within the <TMPERINIT> and select
all.
............................................................................................................................................................................
Step 3
Click
Send
to issue the command.
Result:
The Response Window should display the command
followed by a
COMPLD
indication.
............................................................................................................................................................................
Step 4
If desired, reconnect the office alarm cable at this time.
............................................................................................................................................................................
Step 5
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps