Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXtend Shelf Horizontal Bay Mount
Initial Circuit Pack Installation
2 - 2 2
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
LNW71 (10/100-PL) (R1.0),
LNW66 (10/100T) (R1.1)
Low Speed Installation
(Optional)
Follow this procedure only if installing LNW71 (10/100-PL), or
LNW66 (10/100T) (Supported starting in release R1.1) circuit packs
into the Metropolis
®
DMXtend shelf.
Step 1
Refer to the engineering job specification. Identify the proper function
group slot (D1 or G1) where the LNW71 (10/100-PL), or LNW66 (10/
100T) circuit pack will be installed.
Important!
The LNW71 (10/100-PL), or LNW66 (10/100T)
(R1.1) circuit pack can only be installed in slot 1 of any function
group.
............................................................................................................................................................................
Step 2
Remove the LNW71 (10/100-PL), or LNW66 (10/100T)(R1.1) from
the packing material.
............................................................................................................................................................................
Step 3
Place the circuit pack into the shelf (slot D1 or G1 as required). Do
NOT engage the circuit pack in the backplane connector.
............................................................................................................................................................................
Step 4
Install a 177D or LNW98 Apparatus Blank into the companion circuit
pack slot (D2 or G2 as required).
Important!
177D or LNW98 Apparatus Blanks are required in all
unused slots D and G to provide proper air flow for cooling.
............................................................................................................................................................................
Step 5
Repeat Step 1 through Step 4 for each additional function group (slot
D1 or G1 as required) slot 1’s to be equipped with LNW71 (10/100-
PL), or LNW66 (10/100T)(R1.1) circuit packs.
............................................................................................................................................................................
Step 6
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps
LNW67 (1G SX) (R1.1) Low
Speed Installation
(Optional)
Follow this procedure only if installing LNW67 (1G SX) (Supported
starting in release R1.1) circuit packs into the Metropolis
®
DMXtend
shelf.