Installation Tests
Local Equipment and Cross-connect Tests
4 - 1 6
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 8
If present, remove the loopback at the DSX-3 associated with the DS3
tributary of the Metropolis
®
DMXtend Function Unit slot being tested.
............................................................................................................................................................................
Step 9
Connect a cable from the DS3 test set transmit connection to the
IN
jack of the DSX-3 associated with the first DS3 tributary of the
Metropolis
®
DMXtend Function Unit slot to be tested.
............................................................................................................................................................................
Step 10
Connect a cable from the DS3 test set receive connection to the
OUT
jack of the DSX-3 associated with the first DS3 tributary of the
Metropolis
®
DMXtend Function Unit slot to be tested.
Result:
The DS3 test set should indicate a blue (AIS) signal is
being received for a DS3 pack.
............................................................................................................................................................................
Step 11
Use the scroll bar in the
Command Builder
window to scroll down to
the
ent-crs-sts1
command.
............................................................................................................................................................................
Step 12
Click on the
ent-crs-sts1
command.
............................................................................................................................................................................
Step 13
Under the
Parameters
section,
<STS1CRSSRC>,
click on
m-1-{1}
.
............................................................................................................................................................................
Step 14
Under the
Parameters
section,
<STS1CRSDST>,
click on
{b}-{1}.
Double click on {b} and choose the Function Group where the LNW16
or LNW39 is located.
Result:
One of the following commands will be displayed in the
Command Builder
window to the left of the
Send
button.
ent-crs-sts1:lt-dmxtend:m-1-1,b-1:ctag::2WAYPR; (Function Group
b)
ent-crs-sts1:lt-dmxtend:m-1-1,d-1:ctag::2WAYPR; (Function Group
d)
ent-crs-sts1:lt-dmxtend:m-1-1,g-1:ctag::2WAYPR; (Function Group
g).
............................................................................................................................................................................
Step 15
Click
Send
to issue the command.
Result:
The
Response Window
should display the command
followed by a
COMPLD
indication.