Installation Tests
LBO Software Settings
...........................................................................................................................................................................................................................................................
4 - 5
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
Double click on {IN} and choose the LBO value determined in Step 8.
Result:
A command similar to the following example should be
displayed in the command window to the left of the
Send
button.
Example:
ent-t3:lt-dmxtend:b-all:ctag:::LBO=IN;
............................................................................................................................................................................
Step 13
Click
Send
to issue the command.
Result:
The
Response Window
should display the command
followed by a
COMPLD
indication.
............................................................................................................................................................................
Step 14
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps