Software Download and Circuit Pack Installation
Circuit Pack Firmware Version Verification
3 - 1 8
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 4
Click
Send
to issue the command.
Result:
The
Response Window
should display output similar to
the following:
rtrv-eqpt:LT-DMXTEND:all:123456;
LT-DMXTEND 93-10-26 16:42:11
M 123456 COMPLD
"main-1::TYPE=OC-3,APP=LNW48,CLEI=,ECI=,SLN=,SSN=S1-2"
"main-2::TYPE=OC-3,APP=LNW48,CLEI=,ECI=,SLN=,SSN=S1-2"
"fn-a-1::TYPE=16DS1PM,APP=LNW39,SSN=25Iss,CLEI=,ECI=,SLN=,VRSN=11.0.1"
"fn-a-2::TYPE=16DS1PM,APP=LNW39,SSN=25Iss,CLEI=,ECI=,SLN=,VRSN=11.0.1"
"fn-b-1::TYPE=3DS3,APP=LNW39,SSN=25Iss,CLEI=,ECI=,SLN="
"fn-b-2::TYPE=3DS3,APP=LNW39,SSN=25Iss,CLEI=,ECI=,SLN="
"fn-d-1::TYPE=10/100-PL,APP=LNW71,SSN=,CLEI=,ECCMODE=STS1,"
"ECI=25CECI,SLN=25Ser,VRSN=2.3.1,VLANTAGMD=IEEE 802.1q mode"
"growth-1::TYPE=28DS1PM,APP=LNW7,CLEI=,EDI=,SLN=,SSN=,VRSN=11.0.1"
"growth-2::TYPE=28DS1PM,APP=LNW7,CLEI=,EDI=,SLN=,SSN=,VRSN=11.0.1"
"sysctl::TYPE=SYSCTL,APP=LNW1,SSN=S2-2,CLEI=,ECI=,SLN=,VRSN=7.4.5”
"shelf::TYPE=,APP=ED-xxxxx,SSN=G1,CLEI=,ECI=,SLN="
;
............................................................................................................................................................................
Step 5
For each circuit pack listed in the Response Window output note the
VRSN= number were displayed and compare it to the table of
Firmware Versions in Chapter four of the Software Release Description
(SRD).
............................................................................................................................................................................
Step 6
On any circuit pack were the VRSN= number did not match the version
number for it in the Firmware Version table in the SRD reseat that
circuit pack and wait 15 minutes.
............................................................................................................................................................................
Step 7
Resend the
rtrv-eqpt
command.
............................................................................................................................................................................
Step 8
Compare the VRSN= number again for the circuit pack just reseated
and if it still does not match the table, refer to 365-372-326,
Metropolis
®
DMXtend Access Multiplexer, Alarm Messages and
Trouble Clearing Guide for detailed troubleshooting procedures.
............................................................................................................................................................................
Step 9
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps