4-4
MAX 3000 Installation and Basic Configuration Guide
Preparing to Configure the MAX
Securing the MAX from unauthorized configuration changes
4
Press the Right Arrow key again to display the Default Security profile:
00-301 Default
> Name=Default
Passwd=
Operations=Yes
Edit Security=Yes
Edit System=Yes
Edit Line=Yes
Edit All Ports=Yes
Edit Own Port=N/A
Edit All Calls=N/A
Edit Com Call=N/A
Edit Own Call=N/A
Edit Cur Call=N/A
Sys Diag=Yes
All Port Diag=Yes
Own Port Diag=N/A
Download=Yes
Upload=Yes
Field Service=Yes
5
Press the Down Arrow key to move the cursor down until it is pointing to the Operations
parameter:
00-301 Default
Name=Default
Passwd=
> Operations=Yes
Edit Security=Yes
Edit System=Yes
Edit Line=Yes
Edit All Ports=Yes
Edit Own Port=N/A
Edit All Calls=N/A
Edit Com Call=N/A
Edit Own Call=N/A
Edit Cur Call=N/A
Sys Diag=Yes
All Port Diag=Yes
Own Port Diag=N/A
Download=Yes
Upload=Yes
Field Service=Yes
6
Press Enter to change the Operations setting from the default value of Yes to No.
7
Press the Left Arrow key to exit the Default Security profile.
The Exit menu appears:
Exit?
> 0=ESC (Don’t exit)
1=Exit and discard
2=Exit and accept