Chapter 10 Program Examples
10-7
10.2 XGT Communication
What is XGT communication?
▶
Protocol defined by LSIS, which is divided into XGT client and XGT server.
▶
XGT Client: requests reading/writing data
▶
XGT server: answer to request of client
System configuration and operation of dedicated service
▶
System configuration
[Figure 10.1] example of dedicated system configuration
▶
Mount XGL-CH2A on no. 0 slot of each PLC
▶
Dedicated service at channel 1
▶
Settings of client
Type
Setting content
CPU
XGK-CPUH
Type
RS-485
Speed
9,600
Data bit
8
Stop bit
1
Parity bit
No
Modem type
No
Conditional flag
200ms
Operation
Writing
Write 1 word of M100 of client to M100 of server
Reading
Read 1 word of D100 of server and save it in M110 of client
▶
Settings of server
Type
Setting content
CPU
XGK-CPUH
Type
RS485
Speed
9,600
Data bit
8
Stop bit
1
Parity bit
No
Modem type
No
Station no.
1