Chapter 7 Program Examples of Positioning
7
-
4
(a) Devices Used
Device
Description
%IX0.1.0
Axis X error reset, output inhibition cancel switch
%IX0.1.1
Axis X axis X floating origin switch
%IX0.1.7
Start switch of axis X
%KX6720
Signal during axis X operation
%KX6721
Error signal of axis X
%KX6864
Axis X start
(3) Operation Data Setting
Step
No.
coordi
nates
Control pattern
Operatio
n pattern
Operatio
n type
Repeat step
Target position
[pulse]
M code
Acc./Dec.
No.
Operation
speed
[pls/s]
Dwell time
[
㎳
]
1
Abso
lute
Position
control
End Single
0
10,000
0
1
1000
100
2
Abso
lute
Position
control
End Single
0
20,000
0
1
1500
100
3
Abso
lute
Position
control
End Single
0
30,000
0
1
2000
100
(4) Operation Sequence
• P0041/%IX0.1.1 (floating origin) switch On : set as the floating origin at the current position
• 3 times of P0047/%IX0.1.7 (start) switch On : 3 times of single operation (steps 1~3). If it is
operating now, the start instruction is not executed.
Summary of Contents for XBC-DN20S
Page 210: ...Chapter 7 Program Examples of Positioning 7 6 2 XEC ...
Page 215: ...Chapter 7 Program Examples of Positioning 7 11 2 XEC ...
Page 220: ...Chapter 7 Program Examples of Positioning 7 16 2 XEC ...
Page 225: ...Chapter 7 Program Examples of Positioning 7 21 2 XEC ...
Page 232: ...Chapter 7 Program Examples of Positioning 7 28 2 XEC ...
Page 237: ...Chapter 7 Program Examples of Positioning 7 33 2 XEC ...
Page 240: ...Chapter 7 Program Examples of Positioning 7 36 ...
Page 309: ...Appendix 4 Dimension App 4 4 XBC DN64H XEC DN64H XEC DP64H XBC DR64H XEC DR64H ...
Page 311: ...Appendix 4 Dimension App 4 6 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 312: ...Appendix 4 Dimension App 4 7 5 Communication module XBL C41 21A XBL EMTA ...
Page 313: ...Appendix 4 Dimension App 4 8 5 Special module XBF AD04A XBF DV04A ...