Chapter 5 Positioning Instructions
5
-
23
(b) Device Used
Device
Description
Data size
Example of setting
M0001
position/speed switching
instruction signal
BIT
-
K4210
signal during axis X
position control
BIT
-
K4201
axis X error
BIT
-
(c) Operation of the Program
• PVT instruction is executed when there is the rising edge of M0001, which was used as the
position/speed switching instruction signal.
• It the position control is going on currently, it is switched into speed control, and the current position
is not preset but only the control method is switched to speed control.
• When using the position/speed switching instruction, make sure that the instruction is not executed
during the speed operation by using the display flag (axis X:K4210, axis Y:K4310) during position
control as the program example above.
• To stop the operation after switching to speed control, use the stop instruction (STP).
Summary of Contents for XBC-DN20S
Page 210: ...Chapter 7 Program Examples of Positioning 7 6 2 XEC ...
Page 215: ...Chapter 7 Program Examples of Positioning 7 11 2 XEC ...
Page 220: ...Chapter 7 Program Examples of Positioning 7 16 2 XEC ...
Page 225: ...Chapter 7 Program Examples of Positioning 7 21 2 XEC ...
Page 232: ...Chapter 7 Program Examples of Positioning 7 28 2 XEC ...
Page 237: ...Chapter 7 Program Examples of Positioning 7 33 2 XEC ...
Page 240: ...Chapter 7 Program Examples of Positioning 7 36 ...
Page 309: ...Appendix 4 Dimension App 4 4 XBC DN64H XEC DN64H XEC DP64H XBC DR64H XEC DR64H ...
Page 311: ...Appendix 4 Dimension App 4 6 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 312: ...Appendix 4 Dimension App 4 7 5 Communication module XBL C41 21A XBL EMTA ...
Page 313: ...Appendix 4 Dimension App 4 8 5 Special module XBF AD04A XBF DV04A ...