Chapter 5 Positioning Instructions
5
-
8
(2) Example of Use of the Instruction
• The floating origin setting instruction is described with the example of the following program.
• The example of use of the FLT instruction is described on the basis of axis X.
(a) Example of the Program
(b) Device Used
Device
Description
M0000
axis X floating origin instruction
signal
K4200
Signal during axis X operation
K4201
axis X error
(c) Operation of the Program
• The FLT instruction is executed when there is the rising edge of M0000, which was used as axis X
floating origin instruction signal.
(Not if axis X is operating or in error)
• If the FLT instruction is executed, the origin is fixed right away at the current position differently
from the origin return, the origin determining signal (axis X:K4204) turns On, and the current
address is preset at 0.
Summary of Contents for XBC-DN20S
Page 210: ...Chapter 7 Program Examples of Positioning 7 6 2 XEC ...
Page 215: ...Chapter 7 Program Examples of Positioning 7 11 2 XEC ...
Page 220: ...Chapter 7 Program Examples of Positioning 7 16 2 XEC ...
Page 225: ...Chapter 7 Program Examples of Positioning 7 21 2 XEC ...
Page 232: ...Chapter 7 Program Examples of Positioning 7 28 2 XEC ...
Page 237: ...Chapter 7 Program Examples of Positioning 7 33 2 XEC ...
Page 240: ...Chapter 7 Program Examples of Positioning 7 36 ...
Page 309: ...Appendix 4 Dimension App 4 4 XBC DN64H XEC DN64H XEC DP64H XBC DR64H XEC DR64H ...
Page 311: ...Appendix 4 Dimension App 4 6 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 312: ...Appendix 4 Dimension App 4 7 5 Communication module XBL C41 21A XBL EMTA ...
Page 313: ...Appendix 4 Dimension App 4 8 5 Special module XBF AD04A XBF DV04A ...