Chapter 5 Positioning Instructions
5
-
73
5.3.11 Position Synchronization Function Block
•As shown below, this is a synchronous start-up instruction with the axis set up by the position
synchronization instruction (APM_SSP) as the sub-axis according to the present position of the main
axis. For details, see 3.1.8.
(1) Position Synchronization Start-up Instruction (
APM_
SSP)
Form
Variable
Data Type
Description
STEP
UINT
Operation step No.
● Setting range: 0 ~ 80
MST_
AXIS
USINT
Main axis
● Setting range: 0 ~ 1(0: X-axis, 1: Y-axis)
MST_
ADDR
DINT
Target position of main axis
● Setting range: -2,147,483,648 ~ 2,147,483,647
(a) Function
•This instruction executes position synchronization start-up to the XGB internal
positioning.
•At the rising edge of the input condition, synchronized start-up instruction is executed, where, the
axis designated as AXIS is the sub-axis and that designated in the MST_AXIS is the main axis.
Summary of Contents for XBC-DN20S
Page 210: ...Chapter 7 Program Examples of Positioning 7 6 2 XEC ...
Page 215: ...Chapter 7 Program Examples of Positioning 7 11 2 XEC ...
Page 220: ...Chapter 7 Program Examples of Positioning 7 16 2 XEC ...
Page 225: ...Chapter 7 Program Examples of Positioning 7 21 2 XEC ...
Page 232: ...Chapter 7 Program Examples of Positioning 7 28 2 XEC ...
Page 237: ...Chapter 7 Program Examples of Positioning 7 33 2 XEC ...
Page 240: ...Chapter 7 Program Examples of Positioning 7 36 ...
Page 309: ...Appendix 4 Dimension App 4 4 XBC DN64H XEC DN64H XEC DP64H XBC DR64H XEC DR64H ...
Page 311: ...Appendix 4 Dimension App 4 6 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 312: ...Appendix 4 Dimension App 4 7 5 Communication module XBL C41 21A XBL EMTA ...
Page 313: ...Appendix 4 Dimension App 4 8 5 Special module XBF AD04A XBF DV04A ...