Chapter 5 Positioning Instructions
5
-
96
(b) Used Device
Device
설
명
MX0
PWM output reference signal
%KX6721 X-axis error state
(c) Operation of the Program
• While MX0 is On which is used as output reference signal, PWM is operated.
(At this time, the X-axis is in operation or errorstatus, the instruction will not be executed.)
• If PWM executed, designated output cycle(500ms for this picture) and designated Off duty
rate(30% for this picture)
Remark
• If APM_PWM instruction is executed, other instruction do not operate. And upper/lower limit
does not work
• If APM_PWM instruction is executed, STP, EMG instruction doesn’t operate. To stop output, Off
the Start-up contact
• If output cycle is changed, when operating APM_PWM, it cannot be applied.
•
PWM applicable version
-XBM-DNxxS: H/W from V2.0, O/S V3.10
-XBC-DN/DPxxH: O/S from V2.03
-XEC-DN/DPxxH: O/S from V1.50
-XBC-DN/DPxxSU: O/S from V1.10
Summary of Contents for XBC-DN20S
Page 210: ...Chapter 7 Program Examples of Positioning 7 6 2 XEC ...
Page 215: ...Chapter 7 Program Examples of Positioning 7 11 2 XEC ...
Page 220: ...Chapter 7 Program Examples of Positioning 7 16 2 XEC ...
Page 225: ...Chapter 7 Program Examples of Positioning 7 21 2 XEC ...
Page 232: ...Chapter 7 Program Examples of Positioning 7 28 2 XEC ...
Page 237: ...Chapter 7 Program Examples of Positioning 7 33 2 XEC ...
Page 240: ...Chapter 7 Program Examples of Positioning 7 36 ...
Page 309: ...Appendix 4 Dimension App 4 4 XBC DN64H XEC DN64H XEC DP64H XBC DR64H XEC DR64H ...
Page 311: ...Appendix 4 Dimension App 4 6 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 312: ...Appendix 4 Dimension App 4 7 5 Communication module XBL C41 21A XBL EMTA ...
Page 313: ...Appendix 4 Dimension App 4 8 5 Special module XBF AD04A XBF DV04A ...