Chapter 3 Operation
12
The DS1 Performance Parameters are listed in Table 3-6, below.
Table 3-6 Performance Parameter List - DS1
Performance
Parameter
Description
Definition (DS1/D4)
Definition (ESF)
ES
Error Second
BPV
1, OOF
1, or CS
1. CRC
1, OOF
1, or CS
1.
BES
Bursty Error Second
1 < BPV < 1544
1 < CRC < 320
SES
Severe Error Second
BPV
1544, or OOF
1
CRC
320, or OOF
1
CSS
Controlled Slip Second
frame slip
1
frame slip
1
OOF
Out of Frame
2 frame bit error in 6
consecutive frame bits
2 frame bit error in 6
consecutive frame bits
LOFC
Loss Of Frame Count
OOF for 2.5 0.5 sec
OOF for 2.5 0.5 sec
UAS
Unavailable Second
10 consecutive SES
10 consecutive SES
BPV
Bipolar Violation
Bipolar Error Count
Bipolar Error Count
ESF
CRC Error,
or Out Of Frame
(not used, always 0)
CRC error or OOF
3.11
LED Operation
The front panel of the single Ethernet port IP-6610 has seven LEDs. They are for: Power, Line, Alarm, WAN
UP, WAN DOWN, Ethernet Link/Active, and Ethernet duplex mode.
LED Indications are listed in Table 3-7,
below.
Table 3-7 Front Panel LED Indication
LED
Color
Indication
POWER
Off
Green
Power off
Power on
ALARM
Off
Red
Normal
Alarm happens
DTE/DCE
Red
Flash Green
Green
Dte unsync
A dte-side loopback is active
Dte sync
L
I
N
E
LINE
Off
Flashing Green
Green
Amber
Flashing Amber
Red
No E1 line card exist
A line-side loopback is active
E1 line frame sync
Receive RAI (Remote Alarm Indication) from E1 line
Receive AIS from E1 line
Loss of Frame Alignment
UP
Green
WAN UP
W
A
N
Down
Red
WAN Down
LINK/ ACT
Off
Green
Flashing Green
No Ethernet connection or Link fail
Link
Active
L
A
N
10/100
Off
Green
10Mbps
100Mbps
Summary of Contents for IP6610
Page 2: ...2011 Loop Telecommunication International Inc All rights reserved Version 33 23 MAR 2011...
Page 76: ...Chapter 11 Port Forwarding Virtual Service 53...
Page 79: ...Chapter 12 QoS 56 Figure 12 1 QoS Application...
Page 119: ...Chapter 20 Setting Up Firmware Configuration Up Download with TFTP Server 96...