TYPES OF OPERATIONS
Logicube ZXi-
10G™ User’s Manual
47
•
DOD
–
Choosing this will instruct the unit to perform a 7-pass wipe
conforming to the DoD 5220.22-M standards.
•
CUSTOM
–
Choosing this will allow the user to specify how many wipe
passes will be performed and what values each pass will be written on
each of the passes selected.
5.4.2.2.2 HPA/DCO
The
HPA/DCO
button will open the HPA/DCO option for wiping. If the drive to
be wiped has HPA and/or DCO that needs to be wiped, select
Yes
for the
corresponding option.
5.4.2.2.3 LBA
By default, this is set to 100% which will wipe all Logical Block Addresses
(LBAs) and will wipe the entire drive (100%). The LBA count can be adjusted
by tapping the
edit
icon.
5.4.2.2.4 PASSES
This Wipe Setting will change depending on the Wipe Pattern
Mode
selected.
•
If
None
was selected, this is not selectable.
•
If
DoD
was selected, all 7 passes will be pre-filled. Users can edit the
pass values by tapping the
edit
icon. The default values are: 00, 01,
00, FF, F6, 00, XX (random).
•
If
Custom
was selected, one pass will be pre-filled with a random
value. Users can edit the pass values if desired by tapping the
edit
icon. The default value for a custom pass is 00.
Editing one or more of the passes in DOD or CUSTOM mode will bring up this
screen:
•
SKIP
–
Instructs the unit to skip the pass.