LK Floor Heating | Assembly Instructions | LK Room Temperature Control ICS-RF8
9
EN.33.C.891008
Switch NO/NC function (illus. 13)
The receiver can be switched to operate actuators either normally closed (NC) or normally open (NO) The
adjustment is done by moving the NC/NO "jumper" to the appropriate position as shown in the illustration
below.
Termination of the network (illus. 13)
When two or more receiving units are connected in a network, the start and end of the network must be identified
for the network to function properly. (NOTE: for further information please see the
BUS
section.)
Setback input (remote control) (illus. 14)
The unit is equipped with an input for remote control temperature reduction, for example, via a GSM switch.
A closed contact enables centralized control for all the thermostats in the system. When activated, all thermostats
show EXT in the display and the temperature is lowered to + 12 degrees (factory set) for all rooms/zones; the
temperature can be adjusted. NOTE: for more information, please see adjustment/setting of the
Thermostat
ICS-RF.
MEM input (illus. 15)
The receiver is equipped with a MEM port that is used primarily when there is to be a system log maintained.
Measurement data is sent to LK ICS MEM Stick once per minute. With the help of measurement data and LK
ICS Analyzer software, the installer can easily verify/analyze the installation.
1. Insert the LK ICS MEM Stick into the MEM port. Please note the date.
2. The green U-LED glows constantly.
3. Remove LK ICS MEM Stick when logging is completed.
4. Transfer the information to the LK ICS Analyzer.
NOTE:
The LK ICS Analyser and LK ICS MEM Stick is only available
to LK’s dealers.
It is also possible to update the device software via the MEM port. Instructions are supplied with all software
updates that may be necessary.
GW input (illus. 16)
Input for real-time logging of device. This feature can only be used by LK Systems because it requires special
programs and expertise.