LK Floor Heating | Assembly Instructions | LK Room Temperature Control ICS-RF8
29
EN.33.C.891008
Limitations
Min
Max
Notes
Number of thermostats per
ICS RF8
1
8
Number of actuators per ICS
RF8
1
12
Number of actuators per
channel ICS
1
3
It is possible to physically connect two per
contact.
Number of radio links per
system
1
1
With connected BUS
Number of ICS-RF 8 per
system
1
8
With connected BUS
Number of channels per
system
1
64
With connected BUS
Maximum number of
repeaters per system
0
4
Length of cable networks
-
75 m
With connected BUS
Cable length for Radio link
(cable type: modular cable
RJ9)
-
30 m
LK Aerial cable is 10 m
Comments
Totally trouble-free operation cannot always be guaranteed with the technology available today that allows free
use of EU authorised frequency bands (interference from other sources is possible). Therefore, each installation
should be tested individually.
Manufacturer set thermostat
Setting
Unit
Min
Max
Factory
settings
Holiday value
Days
1
90
1
Setback temperature °C
8
40
12
Economy
temperature
°C
8
40
18
Comfort temperature °C
8
40
20
Holiday temperature °C
8
40
12
Start time Comfort
Time, hours
00:00
24:00
06:00
Start Time Economy Time, hours
00:00
24:00
22:00
System clock
Number of days:
hours: minutes
0:00:00 7:23:59
1:00:00
Floor sensor min limit °C
7
40
10
Floor sensor max limit °C
7
40
27
Adaptive function
On/Off
-
-
Off
Background lighting
display
On/Off
-
-
Off
Key lock
On/Off
-
-
Off