LK Floor Heating | Assembly Instructions | LK Room Temperature Control ICS-RF8
22
EN.33.C.891008
of the whole floor. The external sensor is slipped into the conduit before laying the floor. Connection instructions
to the room thermostats are given above.
LK Clip Rail 12
Sheath in conduit approx. 2 meters into the room before embedding in concrete; consider location for the sensor
carefully as it must be representative of the whole floor. The end of the sensor must be placed between two
floor heating pipes. Seal the end of the conduit with tape or similar to prevent concrete entering the conduit
bore. Position the conduit as close to the surface as possible as this provides optimum control of floor surface
temperature. Install the cable sensor prior to pouring concrete. The external sensor is slipped into the conduit
before pouring the concrete. Connection instructions to the room thermostats are given above.
Delete channels
If required, all initialised channels can be deleted, for further information please see
Reset
section.
Delete individual channels
If necessary, a single channel/thermostat can be deleted from the receiver unit.
1. Press the L key on the receiver unit for at least 3 seconds, L-LED will light green.
2. Press the left arrow and right arrow key on the thermostat for at least 5 seconds.
3. The DEFA text flashes on the display, confirm with
Mode
.
4. The text RUR is shown in the display.
5. Remove the battery for at least five seconds.
6. The unit is now cleared of all settings and is ready to be re-initialised.
7. End the sequence by pressing the L key on the receiver unit, following which the L-LED goes out.
Battery replacement
LK Room Thermostat RF ICS comes with three 1.5 volt LR03 batteries (AAA). The batteries have a life
expectancy of two years. Life expectancy is affected by the user's choices, such as activated background lighting.
The thermostat display has a battery icon that shows the battery status. The battery should be replaced when
the icon only shows one segment.
Battery replacement is performed as follows:
1. Remove the thermostat from the wall by gently pushing the securing plate with a screwdriver while at
the same time pulling the thermostat from the back-plate (the push-lock is positioned on the underside
of the thermostat).
2. Replace the batteries and then click the thermostat into position again. After the battery replacement,
the thermostat automatically returns to normal operation.