LK Floor Heating | Assembly Instructions | LK Room Temperature Control ICS-RF8
16
EN.33.C.891008
1. Increase/decrease the temperature by using the +/- key
2. Press
Mode
once when the temperature is flashing.
3. Symbol for constantly disconnected weekly programs appear on the display, see illus. 5 in the display
above. The display shows neither the
Comfort
nor
Economy
mode as the program is constantly
disconnected.
The constant disconnection of the weekly program is cancelled when you press
Mode
for 4 seconds. The display
will then show the
Comfort
or
Economy
mode in the operating part of the display (see illus. 12 in the above
display image).
Holiday mode – set the temperature
The thermostat is equipped with a so-called "holiday function", enabling any thermostat to activate a general
drop in temperature in the unit for a selected number of days. The temperature is factory preset to +12°C degrees.
The temperature can be changed for individual thermostats as follows:
1.
Press
Mode
until
flashes, confirm with
Mode
.
2. Select right arrow until
Holi
(Holiday) is displayed, confirm using
Mode.
3. Set the desired temperature using the left/right arrow, confirm using
Mode.
Repeat the above for other thermostats in the system.
Holiday mode – activate
The function is activated from any thermostat as follows:
1.
Press
Mode
until
flashed.
2.
Select
using the right arrow, confirm with
Mode
.
3. Select
ON
, confirm with
Mode
.
4. Select the number of days with the left/right arrow, confirm with
Mode
.
Now all thermostats should show the selected number of days in the display, counting down the days. When
the days reach "zero" the thermostat returns to the program each thermostat was running prior to the holiday