44
4.3.2 Control Circuit Wiring
The applicable functions in parameter Group E can be assigned to multi-function digital inputs (S1 to
S8), multi-function relay outputs (R1, R2), multi-function digital outputs (D1, D2), multi-function
analog input (A1, A2) and multi-function analog output (FM, AM). The default settings are listed in
Figure 4.3.1.1 and Figure 4.3.1.2.
For safety, always check the emergency stop operation after wiring. Emergency stop circuit is
necessary to stop the drive immediately in a safe manner to prevent any injuries.
Do not remove the drive covers or touch the circuit boards when the power is on. Failure to
comply could cause electrical shocks to personnel.
Separate control circuit wiring from main circuit wiring and other power lines. Failure to
comply could cause drive malfunction.
Insulate shielded cable with tape to avoid contact with equipment and other signal lines.
Improper insulation could cause drive or equipment malfunction.
Always use shielded twisted-pair cables to prevent drive and equipment malfunction cause by
electrical interference.
Ground the shield to the ground terminal of drive. Failure to comply could cause erroneous
operation or damage to the drive and equipment. Wire ground terminal and main circuit
terminals before wiring control circuit terminals.
Summary of Contents for EVO 8000 Series
Page 1: ......
Page 3: ...7 4 MODBUS Data List 142 APPENDIX UL DESCRIPTION 156...
Page 15: ...12 2 2 Nameplate Model Number Applicable motor rating Input power supply Output power supply...
Page 48: ...45 4 3 2 1 Multi Function Digital Input Wiring Diagram...
Page 49: ...46 4 3 2 2 Pulse input wiring diagram...
Page 55: ...52 F1 F4 F5 F6 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON...
Page 169: ...166 22F 392 Ruey Kung Road Neihu Taipei City 114 Taiwan...