100
Parameter
Name
Description
Setting Range
Interval Time
attempts.
Min.: 0.5 s
Max.: 600.0 s
P6: Overtorque
/
Undertorque Detection
P6-00
Overtorque
/
Undertorque
Detection Selection
1
Sets the operation when the motor current or
torque exceeds the P6-01 level for longer than the
time set to P6-02.
0 : Disabled
1 : Overtorque Alarm at Speed Agree
2 : Overtorque Alarm at Run
3 : Overtorque Fault at Speed Agree
4 : Overtorque Fault at Run
5 : Undertorque Alarm at Speed Agree
6 : Undertorque Alarm at Run
7 : Undertorque Fault at Speed Agree
8 : Undertorque Fault at Run
Default: 0
Range: 0 to 8
P6-01
Overtorque
/
Undertorque
Detection Level 1
Sets the level for overtorque/undertorque
detection 1.
Default: 150%
Min.: 0 %
Max.: 300 %
P6-02
Overtorque
/
Undertorque
Detection Time 1
Sets the time for overtorque/undertorque
detection 1.
Default: 0.1 s
Min.: 0.0 s
Max.: 10.0 s
P6-03
Overtorque
/
Undertorque
Detection Selection
2
0 : Disabled
1 : Overtorque Alarm at Speed Agree
2 : Overtorque Alarm at Run
3 : Overtorque Fault at Speed Agree
4 : Overtorque Fault at Run
5 : Undertorque Alarm at Speed Agree
6 : Undertorque Alarm at Run
7 : Undertorque Fault at Speed Agree
8 : Undertorque Fault at Run
Default: 0
Range: 0 to 8
P6-04
Overtorque
/
Undertorque
Detection Level 2
Sets the level for overtorque/undertorque
detection 2.
Default: 150%
Min.: 0%
Max.: 300%
P6-05
Overtorque
/
Undertorque
Detection Time 2
Sets the time for overtorque/undertorque
detection 2.
Default: 0.1 s
Min.: 0.0 s
Max.: 10.0 s
P6-06
Mechanical
Weakening
Detection
Operation
Sets the speed range to detect mechanical
weakening and the operation when detected.
0 :Disabled
1 : Continue Operation if the Speed (Signed) is
above P6-07
2 : Continue Operation if the Speed (Unsigned) is
Default: 0
Range: 0 to 8
Summary of Contents for EVO 8000 Series
Page 1: ......
Page 3: ...7 4 MODBUS Data List 142 APPENDIX UL DESCRIPTION 156...
Page 15: ...12 2 2 Nameplate Model Number Applicable motor rating Input power supply Output power supply...
Page 48: ...45 4 3 2 1 Multi Function Digital Input Wiring Diagram...
Page 49: ...46 4 3 2 2 Pulse input wiring diagram...
Page 55: ...52 F1 F4 F5 F6 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON...
Page 169: ...166 22F 392 Ruey Kung Road Neihu Taipei City 114 Taiwan...