77
Parameter
Name
Description
Setting Range
C6-00
Carrier Frequency
Selection
Sets the switching frequency of the drive output
transistors. Adjust this setting to reduce audible
noise and leakage current.
2: 2.0 kHz
4: 4.0 kHz
8: 8.0 kHz
12: 12.0 kHz
16: 16.0 kHz
Default: Determined by
A1-02 and o2-03.
Range: 2 to 16
C9:
PM motor speed estimator
C9-00
Operating current
command in I/f
control state
Sets the I/f running current command (%)
depending on the load, so that the rated current
of the inverter is 100%.
Default
∶
80 %
Min.: 0 %
Max.: 150 %
C9-01
Switch to the
maximum current
decay time of the
PM open loop
vector control
Adjust the current decay time when I/f switches to
open-loop vector control.
Default
∶
2.0 s
Min.: 0.1 s
Max.:
20.0 s
C9-02
High frequency
switching point of
hysteresis curve
Adjust the frequency of the high frequency
switching point in the hysteresis curve
Default
∶
15.0 Hz
Min.: (C9-03 + 0.1) Hz
Max.:
500.0 Hz
C9-03
Low frequency
switching point of
hysteresis curve
Adjust the frequency of the low frequency
switching point in the hysteresis curve
Default
∶
10.0 Hz
Min.: 0 Hz
Max.:
(C9-02 - 0.1) Hz
C9-04
Damping coefficient
of PM speed
estimator
Adjust the rise time of the speed estimator output
signal.
Default
∶
0.7
Min.: 0
Max.: 2.0
C9-05
The natural
frequency of the
PM speed estimator
Adjust the response bandwidth of the speed
estimator output signal.
Default
∶
60
Min.: 0
Max.: 200
C9-06
PM angle estimator
error
Monitor the amount of error in the non-sensing
vector control estimation angle
-
Group L, Frequency Command
L1: Frequency Command
L1-00 <4> Frequency
Default:5.00Hz
Summary of Contents for EVO 8000 Series
Page 1: ......
Page 3: ...7 4 MODBUS Data List 142 APPENDIX UL DESCRIPTION 156...
Page 15: ...12 2 2 Nameplate Model Number Applicable motor rating Input power supply Output power supply...
Page 48: ...45 4 3 2 1 Multi Function Digital Input Wiring Diagram...
Page 49: ...46 4 3 2 2 Pulse input wiring diagram...
Page 55: ...52 F1 F4 F5 F6 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON...
Page 169: ...166 22F 392 Ruey Kung Road Neihu Taipei City 114 Taiwan...