specialist is familiar with the rules and requirements relevant to
their activity and to explosion protection, especially ATEX
Directives 2014/34/EU and 1999/92/EC.
Qualified electrician
A person with appropriate technical training, knowledge, and
experience who can recognize and avoid the hazards that may
arise from electricity.
1.5 Foreseeable misuse
Any usage of the product other than as specified in this manual
is strictly prohibited and will invalidate its ATEX approval.
Particularly prohibited are:
•
Use outside the specified ambient temperature range.
•
Use of non-specified consumables.
•
Use of dirty lubricants or lubricants with air inclusions.
•
Use of C3 versions in areas with aggressive, corrosive
substances (e.g., high salt load).
•
Use of plastic parts in areas with high exposure to ozone, UV
light, or ionizing radiation.
•
Use to supply, convey, or store hazardous substances and
mixtures as defined in the CLP Regulation (EC 1272/2008) or
GHS with acute oral, dermal, or inhalation toxicity or
substances and mixtures that are marked with hazard
pictograms GHS01-GHS06 and GHS08.
• Use to supply, convey, or store Group 1 fluids classified as
hazards as defined in the Pressure Equipment Directive
(2014/68/EU) Article 13 (1) a).
•
Use to supply, convey, or store gases, liquefied gases,
dissolved gases, vapors, or fluids whose vapor pressure
exceeds normal atmospheric pressure (1013 mbar) by more
than 0.5 bar at their maximum permissible operating
temperature.
•
Use to supply, convey, or store lubricants containing volatile
solvents.
•
Use without proper safeguards against excessively high
pressures, in the case of pressurized products.
•
Use in a different, more critical explosion protection zone than
that specified on the type plate.
•
Use with a finish or paint coat applied improperly after
delivery. The finish or paint coat must meet the requirements
of the standards applicable to ATEX.
•
Use in potentially explosive gases and vapors whose ignition
temperature is less than 125% of the maximum surface
temperature.
•
Use in potentially explosive dusts whose minimum ignition
temperature and glow temperature are less than 150% of the
maximum surface temperature.
•
Use of lubricants with temperatures above the maximum
permissible ambient temperature.
• Use while failing to observe the prescribed repair and
maintenance intervals or the referenced documents.
1.6 Referenced documents
In addition to this manual, the following documents must be
observed by the respective target group:
•
Company instructions and approval rules
If applicable:
•
Safety data sheet of the lubricant used
•
Project planning documents
•
Supplementary information regarding special designs of the
pump. This you will find in the special system documentation.
•
Instructions for other components for setting up the
centralized lubrication system.
1.7 Prohibition of certain activities
The following activities must be performed only by employees of
the manufacturer or authorized persons due to possibly
undetectable sources of error or due to statutory requirements:
•
Repairs, modifications to the attachments, e.g. sensors
•
Repairs, modifications to the monitoring equipment
•
Replacement, modifications to the nozzles and the pressure
balance of the throttle bushing
1.8 Painting plastic components and
seals
The painting of any plastic components and seals of the
products described is prohibited. Completely mask or remove
plastic components before painting the main machine.
1.9 Safety markings on the product
Symbol for equipotential bonding connections on the
product
1.10 Notes on the type plate
The type plate provides important data such as the type
designation, order number, and sometimes regulatory
characteristics. To avoid loss of this data in case the type plate
becomes illegible, it should be entered in the manual.
Fig. 1
Type plate of the SMBM-X