![Lincoln SKF SMBM-V EEX Operating Instructions Manual Download Page 51](http://html1.mh-extra.com/html/lincoln/skf-smbm-v-eex/skf-smbm-v-eex_operating-instructions-manual_1917702051.webp)
51
4.
Connect the flexible cable leads to terminals [1] and [4] on
cable socket (
3
) in accordance with the terminal diagram (see
Fig. 35).
5.
Attach and tighten the connection socket (
3
) to the housing
(
4
).
6.
On the housing (
4
), use a cable gland (
5
) to tighten the conical
ring (
6
) securely.
7.
Check the threaded joint for leak-tightness.
NOTE
Ensure that the ATEX connection cable provided by the
customer is secured against strain and twisting. Secure the
ATEX connection cable accordingly if necessary.
8.
Attach the complete cable socket (
1
) to the signal transmitter
(
2
) and screw it tightly.
9.
Arrange the ATEX connection cable from the signal
transmitter to the port without any kinks.
Fig. 34
Assembly and switch settings of the signal
transmitter 24-1072-2125
Fig. 35
Connection socket, interior view
Fig. 36
Individual parts, cable socket