![Lincoln SKF SMBM-V EEX Operating Instructions Manual Download Page 46](http://html1.mh-extra.com/html/lincoln/skf-smbm-v-eex/skf-smbm-v-eex_operating-instructions-manual_1917702046.webp)
46
Table 34
Attachment dimensions A/B/C/D for SMBM-V with maximum number of attached modules
Dimensions [mm]
1 Module
2 Modules
3 Modules
4 Modules
5 Modules
6 Modules
A
1)
205.5 286.5 367.5 448.5 529.5 610.5
B
[±1]
1)
181.5 262.5 342.5
424.5
505.5 586.5
C
2)
220.5 301.5 382.5 463.5 544.5 625.5
D
[±1]
2)
181.5 262.5 342.5 424.5 505.5 586.5
1)
with changeover valve
2)
with changeover valve and filter with shut-off valve
Table 35
Weight of base plate with filter and shut-off valve 2.84 kg
Weight of base plate for changeover valve with valve plate 1.61 kg
Weight [kg]
1 Module
2 Modules
3 Modules
4 Modules
5 Modules
6 Modules
Total weight of
SMBM-V with
number of
modules
2.82
4.91
7.00
9.09
11.18
13.27
NOTE
The weight specifications refer to complete flow limiter assemblies without monitoring, attachments and screw unions. Weight
specifications for monitoring units and attachments, see Chapter 4.
IMPORTANT NOTE
Flow limiters are often used in application areas in which strong vibrations and jolts can occur. For reasons of safety
during assembly (fastening screws M6 (2x)), a total overall length of six SMBM modules should therefore not be exceeded.