10. Cleaning
<
WARNING
Electric shock
Perform cleaning work only on products that have
been de-energized and depressurized. Do not
touch cables or electrical components with wet or
moist hands. Use steam-jet equipment or high-
pressure cleaners only in accordance with the IP
enclosure rating of the components. Otherwise,
electrical components may be damaged. Cleaning,
required personal protective gear, cleaning
agents, and equipment are in accordance with the
current operating rules of the operator.
10.1 Cleaning agents
Only cleaning agents compatible with the materials can be used
for cleaning (for materials, see Chapter 2. "Material
compatibility").
NOTE
Always completely remove any cleaning agent residue on
the product and rinse with clear water. This prevents the
formation of alkaline deposits.
10.2 Exterior cleaning
•
Mark and secure wet areas
•
Unauthorized persons must be kept away
•
Thoroughly clean all external surfaces with a moist cloth
NOTE
The flow limiters must be kept closed without fail during
cleaning.
10.3 Interior cleaning
The interior normally does not need to be cleaned.
The interior of the product must be cleaned if incorrect or
contaminated lubricant is accidentally filled. Please contact SKF
Customer Service.
10.4 Cleaning of the pulse generator
If the active sensor surface becomes contaminated with
lubricant, it must be cleaned with a cloth.