![Lincoln SKF SMBM-V EEX Operating Instructions Manual Download Page 52](http://html1.mh-extra.com/html/lincoln/skf-smbm-v-eex/skf-smbm-v-eex_operating-instructions-manual_1917702052.webp)
52
6.9 Electrical connection of changeover
valve 24-1254-3437
For electrical data of the ATEX 3/2 changeover valve (directional
solenoid valve), see Chapter 4.4
•
Connect directional solenoid valve in accordance with the
terminal diagram in Figure 37.
Fig. 37
Connecting directional solenoid valve 24-1254-3437
Table 37
Legend to Figure
37
Item Designation
<Content>
1 Screwed gland (2x)
2 Cover fittings (4x)
3 Lids
4 Terminal box
5 Directional solenoid valve
6 Operating voltage connection 0.75 to 1.5 mm
2
7 Protective earth conductor max. 1.5 mm
2
8 Equipotential bonding connection 4 mm
2
9 Pull-out dimension 80 mm
1.
Loosen the screwed gland (
1
) (2x).
2.
Loosen cover fittings (
2
) (4x) and put to the side along with
the cover (
3
).
3.
Guide the connection cable through the screwed gland (
1
) and
the terminal box (
4
).
4.
Connect directional solenoid valve (
5
) in accordance with
terminal diagram in Figure 37.
5.
Tighten the screwed gland (
1
) (2x).
6.
Place the cover (
3
) on the terminal box (
4
), tighten the cover
fittings (
2
) (4x).
Table 38
Spare parts/accessories
Designation Item
number
<Content>
3/2 changeover valve
24-1254-3437
II 2G Ex e mb IIC T4 Gb
6.10 Lubrication line connection
<
CAUTION
Risk of slipping
Exercise caution when handling lubricants.
Immediately bind and remove any leaked
lubricants.
<
IMPORTANT NOTE
Tension-free connection
Connect the lubricant lines in such a way that no
forces are transferred to the product.
All components of the centralized lubrication system must be
designed for:
•
The maximum pressure that occurs
•
The permissible temperature range
•
The delivery volume and the lubricant to be supplied.
<
IMPORTANT NOTE
Overpressure
Secure the centralized lubrication system against
excessive pressure using an appropriate pressure
relief valve.
Observe the following mounting instructions for safe and
trouble-free operation:
•
Use only clean components.
•
The flow of lubricant should not be impeded by the mounting
of sharp bends, angle valves, flap valves, seals protruding
inward, or changes in cross-section (large to small).
Unavoidable changes in the cross-section in lubrication lines
must have smooth transitions.
•
Use only grounded steel pipes.