![Lincoln SKF SMBM-V EEX Operating Instructions Manual Download Page 24](http://html1.mh-extra.com/html/lincoln/skf-smbm-v-eex/skf-smbm-v-eex_operating-instructions-manual_1917702024.webp)
24
Fig. 7
Functional diagram SMBM-V
Table 8
Legend to Fig. 7
Item Designation
1 Inlet volume flow
(5)
Q
in
(D
1
)
/starting state and inlet
volume flow
(6)
Q
in
(D
2
)
/operating state
2 Outlet volumetric flow
Q
out
3 Inlet
pressure
p
1
upstream of
D
1
/D
2
4 Control
piston
SK
5 Plug-in
nozzle
D
1
(nonadjustable restrictor)
6 Plug-in
nozzle
D
2
(nonadjustable restrictor)
7 Variable
restrictor
D
3
8 Inner
pressure
p
2
downstream of
D
1
/D
2
9 Spring
force
F
10 Stop
screw
AS
11 Signal
transmitter
SG
(optional)
12 Outlet
pressure
p
3
downstream of
D
2
(back pressure
in the system)
13 Gear-type flow indicator with pulse generator
NOTE
Instead of the stop screw (Item: 10), a signal transmitter