6.8. Control menu
The menu gives the opportunity to setup those channels which can be used to connect or
control third party devices.
Figure 6-7. Control menu (RS-232 tab)
6.8.1. RS-232 tab
General Settings
There are three RS-232 working modes: Pass-
through-, Control- and Command Injection modes.
See more details in section
Port settings
Two ports are available:
Local: Serial connection between the CPU
and the 3-pole Phoenix connector
Link: Serial connection between the CPU
and the receiver unit (via TPS line)
The settings are the same but different parameters
can be set for Local and Link ports.
Command injection
If the Command injection mode is selected, this
section is activated and the port number can be set.
Default value is 8001 (local), and 8002 (link).
Control protocol
The active protocol can be set by the drop-down
menu: LW2 or LW3 protocol.
Other
The terminal line can be used to send commands to
the destination in pass-through mode.